| Innovations 2009 |
|
|
| |
|
|
|
|
| |
|
|
 |
|
NEW LCP Standard, 800 mm deep
- Cooling output up to 15 kW
- Space-saving depth of only 800 mm
- Even air distribution over the entire height of the unit
- Integral condensation and leak management
- BMS connection with SNMP or floating contact
Your benefits:
- 800 mm deep means you can even use it on existing 800 mm racks
- Space-saving
- Cooling for customised applications
|
| |
|
|
| |
|
top |
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
 |
|
NEW LCP Inline, 42" (1066 mm) deep variant for the USA
- Cooling output up to 30 kW
- Installation within a row of racks
- Combination with Rittal cold aisle containment system (cold/warm)
- No raised floor needed
- Network-compatible
- 42" deep for use in the USA
Your benefits:
- Cools several racks
- Redundancies can be depicted easily
- High level of efficiency in combination with cold aisle containment system by achieving high delta T's on the air side
- Can also be used for the room cooling
- No raised floor needed
|
| |
|
|
| |
|
top |
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
 |
|
NEW LCP plus EC
- Features identical with LCP plus
- Touchscreen
- Easy replacement of fan
- Network-compatible
- 50% less electrical power consumption by using highly efficient EC fan technology
Your benefits:
- High density cooling up to 30 kW
- Reduction of operating costs by EC technology
- High level of performance with high water inlet temperatures -> Free Cooling
- Perfect control of cold air temperature owing to fan speed control and 2-way stop valve
|
| |
|
|
| |
|
top |
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
| |
|
| |
|
|
 |
|
NEW LCP Smart
- Cooling output up to 20 kW
- Touchscreen as an optional accessory
- Use of highly efficient EC fans
- Easy replacement of fan
- Easy replacement of water components
- Network-compatible
- Extremely robust thanks to simple, optimised configuration
Your benefits:
- Reduction of operating costs by EC technology
- Short servicing times during filter or water component replacement
- Single-phase and three-phase connection possible
- Perfect control of cold air temperature owing to fan speed control and 2-way stop valve
|
| |
|
|
| |
|
top |
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
| |
|
| |
|
|
 |
|
NEW LCP T3+
- Fully redundant cooling output up to 24 kW
- Redundant heat exchanger
- Redundant power supply via integral transfer switch
- Two external connection units for water, to mount in, e.g., the raised floor
- High level of performance with high water intlet temperatures -> Free Cooling
- Software with auto-balancing and auto-recovery functions
- Optional EC design
Your benefits:
- Redundant power and water supply
- Ultimate reliability through redundancy
- Short servicing times during filter or water component replacement
- Simple, organised construction
- Extremely service-friendly
- Perfect control of cold air temperature owing to fan speed control and 2-way stop valve
» Further information PDF, 503 KB
|
| |
|
|
| |
|
top |
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|